{{ variable.name }}

The 54 kWh FlexAIO configuration is one complete residential cluster: six 9 kWh battery modules stacked beneath the integrated inverter cabinet, with a built-in backup port for whole-home backup without STS switching. It is the configuration chosen when a single 6 kWh or 9 kWh pack is not enough for the household load profile and the project needs storage measured in tens of kilowatt-hours rather than single packs.
Every module in the stack carries its own independent DC optimisation module, so the cluster is optimised pack by pack and continues to operate safely if a single pack fails. Up to six clusters can be run in parallel, taking the platform to a maximum of 324 kWh, and because the FlexAIO design supports mixing 6 kWh and 9 kWh packs — and new with existing batteries — a cluster can be built out in stages instead of being purchased in one step.
Each cluster supports up to six stacked modules, giving 6 to 54 kWh per cluster depending on the 6 kWh and 9 kWh pack mix.
Up to six clusters can be connected in parallel, expanding total residential capacity to a maximum of 324 kWh.
Mixing 6 kWh and 9 kWh packs, and new with existing batteries, improves cost-effectiveness by up to 33% for phased projects.
Independent DC optimisation modules provide intelligent cluster-level management, and the system keeps running safely if one pack fails.
The built-in backup port enables whole-home backup with on-grid to off-grid transfer in under 10 ms, without an external STS switch.
| Cluster nominal energy | Up to 54 kWh (six stacked 9 kWh modules) |
|---|---|
| Module options | 6 kWh and 9 kWh packs; mixing permitted within one system |
| Battery chemistry | LiFePO4, A+ grade 314 Ah cells |
| Cell cycle life | ≥10,000 cycles |
| Max charge / discharge power per 6 kWh pack | 3 kW continuous, 4.5 kW peak (10 s) |
| Max charge / discharge power per 9 kWh pack | 4.5 kW continuous, 6.75 kW peak (10 s) |
| Modules per cluster | Up to 6 stacked modules |
| Clusters in parallel | Up to 6 |
| Maximum expandable capacity | 324 kWh |
| Backup transfer | Whole-home backup without external STS; transfer <10 ms |
| Off-grid overload | 150% for 10 seconds |
| PV oversizing | Up to 200% |
| Ingress protection | IP66; C5-M anti-corrosion |
| Operating temperature | Minus 20 to 55 degrees Celsius with standard battery heating and active cooling |
| Management and digital layer | Per-pack DC optimisation, five-layer hardware redundancy protection, Solis AI with generator support, OTA upgrades, VPP channel with open protocol |
| Single cluster | Up to 6 stacked modules, 6 to 54 kWh |
|---|---|
| Full 54 kWh cluster | Six 9 kWh modules stacked in one cluster with the integrated inverter cabinet |
| Mixed cluster | 6 kWh and 9 kWh modules combined, with old and new batteries mixed for up to 33% better cost-effectiveness |
| Multi-cluster system | Up to 6 clusters in parallel, 324 kWh maximum |
A+ grade 314 Ah LiFePO4 cells with cell-level safety protection are assembled into 6 kWh and 9 kWh packs, each with its own independent DC optimisation module. Packs stack inside a single cabinet that also houses the hybrid inverter and the built-in backup port, using an integrated stackable design that assembles in as little as five minutes. Five-layer hardware redundancy protection is standard at system level. Thermal management uses standard battery heating and active cooling, and the IP66 enclosure carries a C5-M anti-corrosion finish.
Cluster size is configurable module by module: a project can start with a partially populated stack and add 6 kWh or 9 kWh packs later, mixing new batteries with existing ones. Cluster count scales to six parallel clusters for 324 kWh. Software-side configuration covers third-party EMS and VPP integration over the open-protocol channel, generator support through Solis AI, and OTA firmware updates.
Send the target cluster size, number of parallel clusters and site conditions to receive a FlexAIO configuration proposal.
Email: sales@solisstorage.com · Phone: 86 574 65802188
Address: No.188 Jinkai Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, China 315712
LinkedIn: Solis on LinkedIn · Facebook: Solis on Facebook
Solis (Ginlong Technologies, SZSE: 300763) was founded in 2005 and operates a 98,114.69 square metre manufacturing facility with 5,000+ employees and 80 GW annual output capacity; 70% of production is exported.